What settings do the DIP switches control?

  • The LQ-850, LQ-950 and LQ-1050 have two 8-position DIP switches.
    These switches are located at the rear of the printer.

    CountrySW 1-1SW 1-2SW 1-3
    USAONONON
    FranceONONOFF
    GermanyONOFFON
    United KingdomONOFFOFF
    DenmarkOFFONON
    SwedenOFFONOFF
    ItalyOFFOFFON
    SpainOFFOFFOFF

    SwitchONOFF
    SW 1-4Graphic CharactersItalic Characters
    SW 1-5Unidirectional GraphicsBidirectional Graphics
    SW 1-6Not UsedNot Used
    SW 1-7CSF EnabledCSF Disabled
    SW 1-80K Input Buffer
    User-Defined
    Characters Enabled
    6K Input Buffer
    User-Defined
    Characters Disabled
    SW 2-112" Page Length11" Page Length
    SW 2-21" Skip over PerfSkip over Perf Inactive

    Interface/ParitySW 2-3SW 2-4
    ParallelOFFOFF
    Serial/EvenOFFON
    Serial/OddONOFF
    Serial/NoneONON

    Baud RateSW 2-5SW 2-6
    9600OFFOFF
    *4800/19200ONOFF
    1200OFFON
    300ONON

    SwitchONOFF
    SW 2-7Tear Off Mode ONTear Off Mode OFF
    SW 2-8CR Produces CR + LFCR Only
    *NOTE - Baud rate of 19200 is available with N9xxxx firmware only.